w0ts / Wishes

Sample import: your samples to the Digitone II over USB, for the sampler mod (v0.22 or later; the +Drive library: v0.31 or later). Chrome or Edge; USB CONFIG on the instrument set to USB MIDI or Overbridge. Close Elektron Transfer first.

1 · Instrument

not connected

Allow MIDI (with SysEx) when the browser asks. Two ports, both named Digitone II: the one this page sends to, and the one it listens on (USB MIDI has one of each).

2 · Transfer

This computer
SlotNameFolderLengthSlicesSize
Drop audio files or folders here
WAV, AIFF, FLAC, MP3, OGG, M4A

Digitone II
NameSize
SlotNameLengthKind
Connect to see the instrument.

Select samples on the left and press Send, or drag them onto the right; audio files dropped straight onto the +Drive go into the folder that is open. Names: the instrument's list shows the whole name (up to 35 characters); the seven letters under it are its short name. A dropped folder's samples get its name as their folder, and its folders stay folders inside it (v0.40 or later on the instrument; six levels at most, deeper files go into the sixth; before v0.40, each path is one folder). Ticked folders are deleted with their samples (v0.35 or later on the instrument; before that, empty folders go on the instrument: +DRIVE, RIGHT). Moving and renaming: on the instrument.

3 · Memory

recordings (kept) what you send
–room for yours
–yours on it now
–to send
–free after sending
–recordings (kept)
–transfer time (estimate)

4 · Transfers

idle

SampleIntoSizeStatus

5 · Firmware

The mod itself (the sample machines, the recorder, PERC and the rest) is a Digitone II OS update file. Every build is checked by the project's ship gate before it is published, and only that exact file (its sha256) is cleared. The Wishes builder builds Wishes in your browser from your own copies of Elektron's stock OS files, and lets you save it only if it is byte for byte the cleared file. Flash it as any Digitone II OS update (Elektron Transfer, or the instrument's SysEx receive), after backing up the +Drive. Upstream's own cleared builds and their notes: the dn2mk2 patcher, FIRMWARE.md.

6 · Diagnostics

For bug reports: asks the instrument what its DSP has seen (needs v0.34 or later, connected above). It only reads. Run it right after power-on, again right after a note goes silent, and once more after a minute with nothing playing; press Copy each time and paste the results into your report.

idle

  

7 · Erase mod data

Before going back to stock firmware (needs v0.39 or later, connected above): erases everything the mod keeps on the +Drive (the samples in the pool, the projects' sample lists, the +Drive library, the mod's settings) and nothing of Elektron's (projects, sounds, presets are untouched). Then restart the instrument. The same is on the instrument: in the sample browser, +DRIVE, RIGHT, ERASE MOD DATA.

idle